사업분야

Home > 사업분야

사업분야

Product
Turntable auto electrolyte filling machine
Brand
SINOPRO

Function Description
• The equipment is mainly used for automatic conventional/vacuum injection of lithium battery with prismatic Al shell battery. The conveyor belt coming material, scan code before filling, shortcircuit & Hi - pot test, Weigh before filling, bad product sorting collection, automatic liquid injection on the fixture, sealing detection before filling, automatic routine, high and low voltage soaking, filling cup residual liquid collection. Filling cup and nozzle clean, after injection liquid conveyer belt clamp, liquid injection after weighing, automatic liquid injection DMC clean nozzle, note on the liquid glue nail, plastic nail detection, conveyor belt discharging, etc.
• njection method: no pressure difference injection inside and outside the battery.
• Prevent the shell from deforming during the positive and negative pressure standing of the battery during liquid injection.
• Shorten the soaking time of battery and improve the efficiency of equipment.
• During liquid injection, the positive pressure of nitrogen inside and outside the battery is ≤ 0.6mpa.
• Add cleaning system of injection cup and injection nozzle before injection to improve injection accuracy and avoid secondary pollution of injection nozzle to battery.
• Add residual liquid connection system after liquid injection to avoid contamination of battery shell by electrolyte.
• Tapered injection nozzle is adopted to avoid the steps of battery injection mouth and the electrolyte at right Angle connection cannot be cleaned.
• The production capacity of the equipment is not limited by the static process time. When the production capacity remains unchanged or increases and the public practice increases, the injection unit can be added to meet the production requirements.

 

Technical Parameters 

Item Common parameter
Outlook Size L 7200 mm × W 6200 mm × H 2800 mm                     
Machine Weight ≈ 15 T
Power rate 15 kW
Power supply AC 380 V / 50 Hz
Air source ≥ 0.7 MPa, 30 L/s (Utilization rate 50%)
Vacuum source ≤ −95 kPa, 60 L/s
Nitrogen L (100–200 mm) × W (100–175 mm)
Scope of applicable                   × T (15–30 mm)
products ≥ GPPM (Total standing time ≤ 25 min)
Equipment output ≥ 99.5%
Qualified rate 0–770 g
Action ± 0.2%
Filling amount ± 0.1 g
Filling pump accuracy                    ± 1.1%
Filling accuracy     ≥ 97%
Weigh accuracy ≥ 0.6 MPa, 60 L/s